13
Configuring Your BPC2
T
he illustration below shows the name and location of each switch, connector and indicator
light on your LCS BPC2 module. The function of each is described on following pages.
A – Track Power Block terminals should be connected to electrically-isolated
track power blocks.
B – Label for the track power block screw terminals.
C – LCS PDI cable inputs. Use either connector.
D – Red LCS PDI activity indicator.
E – Program switch used to set the BPC2’s TMCC ID base address.
F – Relay Power terminals
Figure 8. BPC2 call outs.
There are three additional steps required to use your BPC2. They are:
1. Connect an accessory transformer to the Relay Power Terminals.
LCS PDI CABLES
use either connector
AC PowerPROGRAM
A U A U
BPC2
BLOCK BLOCK
COMM
COMM
8 7 6 5 4 3 2 1
6-81640
A
B
2. Set the BPC2’s configuration.
3. Wire your track power blocks to the BPC2.