Accessories
Many accessories to be used alongside the existing BPC product portfolio
Port Multiplexer
Allows two devices to be connected to a single RS232 serial
communication port on a UPS. It can be used when a separate
Intelligent Power Management interface and Remote Monitoring Panels
are both required.
MODBUS Adaptors
BPC have a wide range of MODBUS/JBUS adaptors that support
RS485 and TCP/IP connectivity to ensure the device provides
continuous, reliable and accurate network monitoring of the UPS
system through a Building Management Systems (BMS).
RS485 Converter
Using a BPC RSC 24 you are able to convert the RS232 interface to
RS485. Should be used if the distance between UPS and its receiving
interface exceeds 20 metres
Customised Interfaces
With a Multi-interface slot various communication combinations are
selectable including additional RS232, AS-400, USB, Dry Contact Relays
and customised packages.
Simple Network Management Protocol
(SNMP) Modules
Using the SNMP module your BPC UPS acts as a network device that
allows monitoring of more than one UPS connected to your network
through the SNMP VIEW software supplied with the module, or you
can monitor the UPS through an Internet/Web browser. It also provides
for automatic shutdown of multiple servers and workstations on the
network using the advanced ClientMate software. SNMP modules can
be internal UPS factory fitted or provided as an external adaptor.
PowerSwitch – Remote Power Manager
The Remote Power Manager is the answer to providing your system with
a safe remote power-up, power-down and reboot. It allows a scheduled
and systematic shutdown or power-up to your individual devices saving
you both time and money. Customised TRAP and Email alerts can
also be sent on predefined criteria. Up to 16 Remote Power Manager
units can be daisy chained to provide control over 128 devices.
Each configuration will have one Master unit and 15 Slave units.
Features:
Supports TCP/IP, SNMP, HTTP, SMTP, PPP, SNTP, TELNET protocol
Connect using 10/100mbps Ethernet, modem dial-up or a phone
Safe power-up, power-down or rebooting
Individually controls each of the eight AC receptacles
from anywhere using standard Web Browser
Remotely and individually reboots locked servers
Receive daily / event alerts
Sequentially apply power to equipment plugged into the RMP
Customised TRAP and e-mail notification
Remote setup support
Environmental monitoring capabilities (humidity, temperature,
smoke, motion, etc)
Remote Viewer
Modem
RJ11
PPP Dial-in
Modem Script
Cable/XDSL
Modem
Router/
IP Share
Power to 8 electrical devices
INTERNET
Remote Power
Manager
Local Viewer
Wireless Smoke
Detector
Net Feeler Lite
Built-in Temperature
and Humidity Sensor
Wireless Security
Sensor
Mobile Phone
Fixed Line Access